RANGE OF PRODUCTS :

Our wide array of Products to ensures accuracy and conformity for significant experiments. We also customize some of our product range and technologies for educational, medical, industrial or other laboratories for better work experience. Our pre sale and post sales support are also admirable and popular among our satisfied clients.

HOT AIR OVEN

hot air oven

INTRODUCTION :

The equipment is ideal for Drying, Sterilization, Baking, Preheating, Conditioning, Curing and many more scientific studies Research, Industrial and Chemical Laboratories.

  • Design : Double walled, the motor fixed at the back / triple walled, ducted air flow type, the motor fixed at the top. The motorized forced air circulation to maintain uniform temperature inside the chamber.
  • Inner chamber : Stainless Steel 304 grade / 316 grade
  • Outer chamber : Mild steel and finished with powder coated/ stainless steel 304 grade.
  • Heaters : Tubular air heater or memmert type heater coiled form for heating.
  • Insulation : Between inner and outer chamber is filled with high grade glass wool/ ceramic fiber insulation, thickness depends on temperature of the inner chamber.
  • Gasket : Asbestos rope or Neoprene rubber or Silicon rubber gaskets for the door to avoid air leakage and temperature loss of hot air oven.
  • Trays : Two/ Three perforated removable stainless steel trays at the fixed distance.
  • Temperature controlled : by Microprocessor based PID temperature controller with dual display (Process value and set value), low and high limit setting, time base controller and CrAl thermocouple/ PT-100 sensor.
  • Temperature Range : 5 °C above ambient to 200°C. / 300°C. /500°C.
  • Temperature Resolution /Sensitivity: 0.1°C
  • Power supply : 230volts single phase /440 volts three Phase (optional) 50Hz, AC supply.
sl.no In liters inner champer size [WXDXH] Cms Power in[watts]
1 42 35X 35 X 35 1200
2 90 45X 45 X 45 1500
3 120 45X 45 X 60 1750
4 210 60X 60 X 60 2000
5 320 60X 60 X 90 3000

HOT AIR OVEN DUCTED AIRFLOW TYPE

HOT AIR OVEN DUCTED AIRFLOW TYPE
  • Triple wall Construction
  • Inner and Inner most chamber made of stainless steel 304 grades / 316 grades as per the requirement.
  • Outer chamber : made of mild steel and finished with powder coated/ stainless steel 304 grades / 316 grades as per the requirement.
  • The gap between the inner and outer chamber is filled with high grade glass wool insulation. Insulation thickness depends on temperature of the inner chamber
  • The motorized forced air circulation is provided at the Top to maintain uniform temperature inside the chamber.
  • Inner chamber is provided with two or three removable steel trays at the fixed distance.
  • Door has been provided with Asbestos rope or Neoprene rubber gasket (optional) or Silicon rubber gasket (optional) to avoid air leakage and temperature loss of hot air oven.
  • Air Heaters are made of high grade Kanthal wires of suitable wattage.
  • Temperature Range: 5°C above ambient to 200°C. / 300°C. /500°C./ optional.
  • Temperature controlled : by Microprocessor based PID temperature controller with dual display (Process value and set value), low and high limit setting, time base controller and CrAl thermocouple/ PT-100 sensor.
  • Temperature Resolution /Sensitivity : 0.1°C
  • Temperature Accuracy : + 0.5°C /1°C
  • Temperature uniformity: + 5°C.
  • Front Panel: Front panel consists of mains ON/OFF rocker switch, temperature controller and instruction manual.
  • Control Panel: Control panel consists of mains ON/OFF rocker switch, temperature controller, heater and motor fuses, solid state relay/ DC relays and wiring.
  • Power supply : 230volts single phase 50Hz, AC supply. /440 volts three phase (optional).
SL.NOLiters CapModel NoInner chamber sizePower in[watts]
190HAO-D-1845x 45 x 451500
2120HAO-D-18/2445X 45 X 601750
3210HAO-D-2460x 60 x 602000
4320HAO-D-24/3660x 60 x 903000
5430HAO-D-24/4860x 60 x 1203500
6500HAO-D-30/3675x 75 x 904000
7650HAO-D-36/24/4890 x 60x 1204500
8730HAO-D-3690x 90 x 905000
9970HAO-D-36/48 90x 90 x 1206000

HOT AIR OVEN

hot air oven
  • Instrument: Double walled, the motor fixed at the back. The motorized forced air circulation to maintain uniform temperature inside the chamber.
  • Inner chamber made of stainless steel 304 grade / 316 grade.(matt or polished finish)optional.
  • Outer chamber made of mild steel and finished with powder coated/ stainless steel 304 grade / 316 grade.(matt or polished finish) optional.
  • Heaters made of high grade Kanthal A-1 wires of suitable wattage. Air heater or memmert type heater coiled form.
  • Insulation Gap of 75/100 mm between inner and outer chamber is filled with high grade glass wool insulation. Insulation thickness depends on temperature of the inner chamber.
  • Gasket Asbestos rope or Neoprene rubber (optional) gaskets for the door to avoid air leakage and temperature loss of hot air oven.
  • Trays Two/ Three perforated removable stainless steel trays at the fixed distance.
  • Temperature Range: 5 °C above ambient to 200°C. / 300°C. /500°C./optional.
  • Temperature Resolution /Sensitivity: 0.1°C
  • Temperature Accuracy : + 0.5°C /1°C
  • Temperature uniformity: + 5°C.
  • Front Panel: Front panel consists of mains ON/OFF rocker switch, temperature controller and instruction manual.
  • Control Panel: Control panel consists of mains ON/OFF rocker switch, temperature controller, heater and motor fuses, solid state relay/ DC relays and wiring.
  • Power supply 230volts single phase /440 volts three phase (optional) 50Hz, AC supply.
  • Temperature controlled by Microprocessor based PID temperature controller with dual display (Process value and set value), low and high limit setting, time base controller and CrAl thermocouple/ PT-100 sensor.
sl.no In liters inner champer size [WXDXH] Cms Outer chamber size [WXDXH] centimeters Power in[watts]
1 42 35X 35 X 35 56x77.5x75 1200
2 90 45X 45 X 45 66x86x84 1500
3 120 45X 45 X 60 66x86x100 1750
4 210 60X 60 X 60 82x92.5x100 2000
5 320 60X 60 X 90 3000

DUCTED AIRFLOW TYPE HOT AIR OVEN

  • Instrument: Triple walled, the motor fixed at the top. The motorized forced air circulation to maintain uniform temperature inside the chamber.
  • Inner and most inner chamber made of stainless steel 304 grade / 316 grade.(matt or polished finish)optional.
  • Outer chamber made of mild steel and finished with powder coated/ stainless steel 304 grade / 316 grade.(matt or polished finish) optional.
  • Heaters made of high grade Kanthal A-1 wires of suitable wattage. Air heater or memmert type heater coiled form.
  • Insulation Gap of 75/100 mm between inner and outer chamber is filled with high grade glass wool insulation. Insulation thickness depends on temperature of the inner chamber.
  • Gasket Asbestos rope or Neoprene rubber (optional) gaskets for the door to avoid air leakage and temperature loss of hot air oven.
  • Trays Two/ Three perforated removable stainless steel trays at the fixed distance.
  • Temperature Range: 5 °C above ambient to 200°C. / 300°C. /500°C./optional. \
  • Temperature Resolution /Sensitivity: 0.1°C
  • Temperature Accuracy: + 0.5°C /1°C
  • Temperature uniformity: + 5°C.v
  • Front Panel: Front panel consists of mains ON/OFF rocker switch, temperature controller and instruction manual.
  • Control Panel: Control panel consists of mains ON/OFF rocker switch, temperature controller, heater and motor fuses, solid state relay/ DC relays and wiring.
  • Power supply 230volts single phase /440 volts three phase (optional) 50Hz, AC supply.
  • Temperature controlled by Microprocessor based PID temperature controller with dual display (Process value and set value), low and high limit setting, time base controller and CrAl thermocouple/ PT-100 sensor.
  • The working chamber size of the hot air oven is given below.

BACTERIOLOGICAL INCUBATOR

bactericol indicator
  • Design : Double walled, the motor fixed at the back / triple walled, ducted air flow type, the motor fixed at the top. The motorized forced air circulation to maintain uniform temperature inside the chamber.
  • Inner chamber : Stainless Steel 304 grade / 316 grade
  • Outer chamber : Mild steel and finished with powder coated/ stainless steel 304 grade.
  • Doors Inner full- length glass door to view the samples without disturbing the temperature. And outer Mild steel door finished with powder coated/ SS 304 grade (optional) door with rubber gasket and lock.
  • Heaters :Tubular air heater or memmert type heater coiled form for heating.
  • Insulation : Between inner and outer chamber is filled with high grade glass wool.
  • Gasket :Neoprene rubber gaskets for the door to avoid air leakage and temperature loss of Bacteriological Incubator.
  • Trays :Two/ Three perforated removable stainless steel trays at the fixed distance.
  • Temperature controlled : by Microprocessor based PID temperature controller with dual display (Process value and set value), low and high limit setting, time base controller and PT-100 sensor.
  • Temperature Range: 5 °C above ambient to 65°C.
  • Temperature Resolution /Sensitivity : 0.1°C
  • Power supply : 230volts single phase 50Hz, AC supply.
SL. NO Capacity in liters Inner chamber size[WXDXH] Cms Outer chamber size[ WXDXH] CMS Power In [watts]
1 42 35X 35 X 35 400
2 90 45X 45 X 45 500
3 120 45X 45 X 60 600
4 210 60X 60 X 60 750
5 320 60X 60 X 90 1000

B O D INCUBATOR

bod indicator

INTRODUCTION :

We are manufacturers of BOD incubators in India since 1995. Our BOD incubators are widely used for day to day bacteriological and bio chemical oxygen demand determination tests in various laboratory applications. We specialize in both standard and customized models, specifically designed to meet the challenging demands of various scientists for individual and specialized research applications.

Salient Features Of BOD Incubator

  • Energy Efficient
  • CFC free cooling
  • Long life
  • Low Maintenance

  • Instruments: Double walled, the motor fixed at the back side. The motorized forced air circulation to maintain uniform temperature inside the chamber.
  • Inner chamber : made of stainless steel 304 grade / 316 grade.
  • Outer chamber: made of mild steel and finished with powder coated/ stainless steel 304 grade / 316 grade.
  • Doors : Inner full- length glass door to view the samples without disturbing the temperature. And outer Mild steel door finished with powder coated/ SS 304 grade (optional) door with rubber gasket and lock.
  • Caster Wheels for easy movable for higher capacity only.
  • Heaters :Indirect heating system is provided in our units, comprising of air heaters made of high grade Kanthal A-1 wires of suitable wattage.. The warm air is evenly distributed throughout the chamber through efficient motor fans ensuring a very good temperature sensitivity.
  • Cooling : An energy efficient cooling unit is installed in our BOD incubators to enable bio chemical demand studies at lower room temperatures. We use ISI marked high end CFC free compressors of Kirloskar/Tecumseh make, conforming to latest international standards and guidelines.
  • Insulation: Gap of 75 mm between inner and outer chamber is filled with high grade glass wool insulation.
  • Gasket: rubber gaskets for the door to avoid air leakage and temperature loss of BOD incubator.
  • Trays: Two / Three perforated removable stainless steel trays at the fixed distance.
  • Temperature Range: +5 °C to 60°C.
  • Temperature Resolution /Sensitivity : 0.1°C
  • Temperature Accuracy : + 0.5°C /1°C
  • Temperature uniformity: + 5°C.
  • Illumination : Our units are provided with door operated illumination system comprising of fluorescent lights.
  • Power supply : 230volts, single phase, /440 volts, three phase, 50Hz, AC supply.
  • Temperature controlled by Microprocessor based PID /Digital temperature controller with dual display (Process value and set value), low and high limit setting, time base controller PT-100 sensor.
Sl. No Liters/cubic Cap/ feet Inner chamber size [WXDXH] Cms Outer chamber size[WXDXH] centimeter Power in[watts]
1 90/3 43x 42x 50 54x84x90 750
2 112/4 50x 45x 50 63x94x98 1000
3 165/6 50x 45x 75 64x90x150 1500
4 285/10 58X55X90 73x102x166 2000
5 340/12 60x 55x 105 74x103x183 3000

TRAY DRIER

try driver

INTRODUCTION :

The equipment is ideal for Drying and many more scientific studies Research, Industrial and Chemical Laboratories.

  • Design : Triple walled, ducted air flow type, the motorized forced air circulation is provided at the Side to maintain uniform temperature inside the chamber and opposite side air Vent provided to disperse the moisture.
  • Inner chamber : Stainless Steel 304 grade / 316 grade.
  • Outer chamber : Mild steel and finished with powder coated/ stainless steel 304 grade.
  • Heaters : Tubular air heater for heating.
  • Insulation :Insulation Between inner and outer chamber is filled with high grade glass wool/ ceramic fiber insulation, thickness depends on temperature of the inner chamber.
  • Gasket : Asbestos rope or Neoprene rubber or Silicon rubber gaskets for the door to avoid air leakage and temperature loss of Tray Drier.
  • Trays : 12, 24, 36 Or 48 as per your requirements, perforated stainless steel sheet tray or Mesh tray removable type at the fixed distance.
  • Temperature controlled : by Microprocessor based PID temperature controller with dual display (Process value and set value), low and high limit setting, time base controller and CrAl thermocouple/ PT-100 sensor.
  • Temperature Range : 5 °C above ambient to 200°C. / 300°C.
  • Temperature Resolution /Sensitivity : 0.1°C
  • Power supply : 230volts single phase /440 volts three Phase (optional) 50Hz, AC supply.
SL. No Liters. Cap Model Inner chamber size [ WXDXH] centimeters Power in [watts]
1 368/12 TD12 84 X 43 X102 2500
2 728/24 TD24 85 x 84 x 102 4000
3 1072/36 TD36 85 x 84 x 150 6000
4 1414/48 TD48 85 x 84 x 198 7500

SEROLOGICAL AND CONSTANT TEMPERATURE WATER BATH

water bath
  • Instruments : Double walled
  • Inner Chamber : made of stainless steel 304 grade / 316 grade.
  • Outer Chamber : made of mild steel and finished with powder coated/ stainless steel 304 grade / 316 grade.
  • Heater Immersed type.
  • Insulation : between inner and outer chamber is filled with high grade glass wool insulation.
  • Heater cover: a perforated sheet cover above the heater is provided only for Serological and Constant temperature.
  • Chamber drain : nozzle at bottom
  • Power supply 230Volts 50Hz single phase AC Supply.
  • Dome type lid : for only Serological and Constant temperature bath, and for Ring water bath concentric rings of diameter 7.5 centimeters
  • Temperature Range : 5 °C above ambient to 95°C.
  • Temperature Resolution /Sensitivity : : for thermostatic + 5°C and for digital + 0.1°C
  • Temperature Accuracy : + 0.5°C /1°C/3°C for digital and + 5°C to 8°C for thermostatic depending on sizes.
  • Temperature uniformity : + 1°C/3°C/ 5°C.
  • Stirrer motor : a circulation stirrer pump for Constant temperature bath and serological water bath to maintain uniformity inside the chamber (optional).
  • Power supply : 230volts single phase /440 volts three phase (optional) 50Hz, AC supply.
  • Temperature controlled : Thermostatic/Microprocessor based PID /Digital temperature controller with dual display (Process value and set value), low and high limit setting, time base controller (optional) PT-100 sensor.
SL. NO. Liters. Cap Inner chamber size[WXLXD] Cms Excluding heater Power In [W]
1 7.5 25x 20 x 15 1000
2 9 30X 20X 15 1000
3 13 35X 25X 15 2000
4 24 40X 30X 20 2000

RING WATER BATH

RING WATER BATH
  • Instruments : Double walled
  • Inner Chamber : made of stainless steel 304 grade / 316 grade.
  • Outer Chamber : made of mild steel and finished with powder coated/ stainless steel 304 grade / 316 grade.
  • Heater Immersed type.
  • Insulation : between inner and outer chamber is filled with high grade glass wool insulation.
  • Heater cover: a perforated sheet cover above the heater is provided only for Serological and Constant temperature.
  • Chamber drain : nozzle at bottom
  • Power supply 230Volts 50Hz single phase AC Supply.
  • Dome type lid : for only Serological and Constant temperature bath, and for Ring water bath concentric rings of diameter 7.5 centimeters
  • Temperature Range : 5 °C above ambient to 95°C.
  • Temperature Resolution /Sensitivity : : for thermostatic + 5°C and for digital + 0.1°C
  • Temperature Accuracy : + 0.5°C /1°C/3°C for digital and + 5°C to 8°C for thermostatic depending on sizes.
  • Temperature uniformity : + 1°C/3°C/ 5°C.
  • Stirrer motor : a circulation stirrer pump for Constant temperature bath and serological water bath to maintain uniformity inside the chamber (optional).
  • Power supply : 230volts single phase /440 volts three phase (optional) 50Hz, AC supply.
  • Temperature controlled : Thermostatic/Microprocessor based PID /Digital temperature controller with dual display (Process value and set value), low and high limit setting, time base controller (optional) PT-100 sensor.
SL. NONo of holesInner chamber size [LXWXD] CmsPower in [W]
1635X 25X 102000
21248X 35X 102000

COOLING WATER BATH

COOLING WATER BATH
  • Design : Double walled
  • Inner chamber made of stainless steel 304 grade / 316 grade
  • Outer chamber : made of mild steel and finished with powder coated/ stainless steel 304 grade / 316 grade.
  • Heaters : Immersed type.
  • Insulation : between inner and outer chamber is filled with high grade glass wool insulation.
  • Heater cover: a perforated sheet cover above the heater is provided.
  • Chamber drain : nozzle at bottom
  • Dome type lid
  • Cooling : An energy efficient cooling unit is installed in our Cooling Water Bath at lower room temperatures. We use ISI marked high end CFC free, hermitically sealed compressors of Kirloskar/Tecumseh make, conforming to latest international standards and guidelines.
  • Temperature Range : +5 °C to 60°C.
  • Temperature Resolution /Sensitivity : 0.1°C
  • Temperature Accuracy : + 1°C /2°C.
  • Temperature uniformity : + 3°C /5°C.
  • Stirrer motor : a circulation stirrer pump for Constant temperature bath and serological water bath to maintain uniformity inside the chamber (optional).
  • Power supply : 230volts single phase /440 volts three phase (optional) 50Hz, AC supply.
  • Temperature controlled : by /Microprocessor based PID Digital temperature controller with dual display (Process value and set value), low and high limit setting, time base controller (optional) PT-100 sensor.
SL. Liters. CapModel NoInner chamber size[LXWXD] Cms Excluding heaterPowerIn [W]
112CWB302020 30 x 20 x 201500
220CWB35302035X 30X202000
324CWB40302040X 30X 202000
435CWB50352050 x 35 x 203000

WATER BATH SHAKER

COOLING WATER BATH
  • Instruments : Double walled
  • Inner chamber : made of stainless steel 304 grade / 316 grade.
  • Outer chamber : made of mild steel and finished with powder coated/ stainless steel 304 grade / 316 grade.
  • Heaters : suitable wattage of Immersed type.
  • Insulation : between inner and outer chamber is filled with high grade glass wool insulation.
  • Heater cover : : top of the heater, a perforated sheet cover is provided.
  • Chamber drain : nozzle at bottom.
  • Dome type lid
  • Shaking : The bath has an oscillating tray riding on ball rollers & oscillated through a governor controlled variable speed DC motor and DC motor drive.
  • Strokes : The shaking action to and fro motion, strokes range is between 40 to 200 strokes per minute.
  • The Oscillating tray has 250/500ml flask (optional).
  • Temperature Range : 5 °C above ambient to 95°C
  • Temperature Resolution /Sensitivity : 0.1°C
  • Temperature Accuracy : + 0.5°C /1°C
  • Temperature uniformity : + 2°C.
  • Power supply : 230volts single phase /440 volts three phase (optional) 50Hz, AC supply.
  • Temperature controlled : by Microprocessor based PID /Digital temperature controller with dual display (Process value and set value), low and high limit setting, time base controller (optional) PT-100 sensor.
Sl.NoTray capacity of flask 250ml or 500mlTray size [WXL]Power in [Watts]
19nos or 6nos12x 132000
212nos or 9nos13x 152000
318nos 12nos13x 192000

OIL BATH

  • Design : Double walled the item supplied excluding oils
  • Inner chamber made of stainless steel 304 grade / 316 grade.
  • Outer chamber made of mild steel and finished with powder coated/ stainless steel 304 grade / 316 grade.
  • Heaters : suitable wattage of frame heater fixed at bottom, beneath the inner chamber.
  • Insulation between inner and outer chamber is filled with high grade glass wool insulation.
  • Heater cover: top of the heater, a perforated sheet cover is provided only
  • Chamber drain nozzle at bottom.
  • Dome/ Plain type lid
  • Temperature Range: 5 °C above ambient to 100°C /200°C /300°C.
  • Temperature Resolution /Sensitivity: for + 0.1°C
  • Temperature Accuracy: + 0.5°C /1°C
  • Temperature uniformity: + 2°C
  • Stirrer motor: a circulation stirrer pump for constant and to maintain uniformity inside the chamber (optional).
  • Power supply 230volts/440 volts, single phase /three phase 50Hz, AC supply
  • Temperature controlled by Microprocessor based PID /Digital temperature controller with dual display (Process value and set value), low and high limit setting, time base controller (optional) PT-100 sensor.
Sl No Liters. Cap Inner chamber size [LXWXD] Cms Outer chamber size[LXWXD] cms Power in [W] for 200°C
1 7.5 25x20x15 1000
2 11 30x25x15 2000
3 17.5 35x25x20 2000

AUTO CLAVE

VERTICAL AUTOCLAVE

autoclave
  • Design : Triple Walled, Three chamber body Jacketed model.
  • Inner and Jacket Chamber : Inner, and Jacket chamber made of stainless steel 304/316 Grade.
  • Outer chamber : Top door ring and outer chamber made of stainless steel 304/316 Grade
  • Insulation : Insulation between inner and outer chamber is filled with high grade glass wool.
  • Heaters : Flanged Type Immersion Heaters are made of high grade Kanthal wires of suitable wattage
  • Gasket: Neoprene/Silicon rubber gasket is provided for the door to avoid steam leakage and air tight pressure proof gasket.li>
  • Top Door Lift:The Door Lifted by Pedal Lifting Arrangements.
  • Door Tightened : The Door Tightened by Fly-Nut Type/ Radial locking system.
  • Accessories Fitted : It Is Provided With Pressure Gauge, Release Valve, Safety Valve, Temperature Indicator cum controller and timer, Pressure Switch (optional), Water Level Indicator, Indicating Lamp of Operation and Drain Valve, Solenoid valve and water inlet valve. water level controller
  • Loading basket :Loading Basket for the suitable size
  • Operating Pressure : Operating Pressure:-20psi (Adjustable)
  • Temperature controlled : Microprocessor based PID Temperature controller with PT-100 Sensor.
  • Temperature Range: 5 °C above ambient to 135°C max.
  • Temperature Resolution: : 0.1°C
  • Temperature Accuracy : ± 1°C.
  • Power supply : 230volts, single phase, /440 volts, three phase, 50Hz, AC supply.
Sl.No Liters./cubic Cap/ feet Model No                                     Inner chamber size Diameter x Depth in mm. Operating voltage and Power                           
1 32 ACV-1218 300 x 450 230VAC,1 ph,50Hz,3KW
2 50 ACV-1420 300 x 500 230VAC,1 ph,50Hz,3KW
3 70 ACV-1624 400X600 230VAC,1 ph,50Hz,4KW
4 100 ACV-1824 450X600 230VAC,1 ph,50Hz,4KW
5 120 ACV-1830 450X750 230VAC,1 ph,50Hz,6KW
6 150 ACV-2030 500X750 440VAC,3ph,50Hz,6KW
7 175 ACV-2230 550X750 440VAC,3ph,50Hz,6KW
8 210 ACV-2236 550X900 440VAC,3ph,50Hz,9KW
9 250 ACV-2436 600X900 440VAC,3ph,50Hz,9KW

HORIZONTAL AUTOCLAVE

autoclave
  • Design : Cylindrical/ Rectangular Triple Walled, Three chamber body Jacketed model.
  • Inner and Jacket Chamber : Inner, and Jacket chamber made of stainless steel 304/ 316 Grade
  • Outer Chamber : Door Plate and outer chamber made of stainless steel 304/316 Grade
  • Insulation : Insulation between Jacket and outer chamber is filled with high grade glass wool.
  • Door : made of 12mm thick stainless steel 304/316(optional) It is tightened by fly nut system or radial locking system (optional) of stainless steel 304grade
  • Heaters : Flanged Type Immersion Heaters are made of high grade Kanthal wires of suitable wattage
  • Gasket : Neoprene/ Silicon rubber gasket is provided for the door to avoid steam leakage and air tight pressure proof gasket.
  • Door Tightened : The door tightened by radial locking system made out of SS 304grade.
  • The Boiler: The Boiler is provided with pressure gauge, plug screen, non-return valve, steam strap, safety valve, release valve, water level indicator, pressure control switch, automatic low water level cut off device and indicating lamp of operation
  • The Jacket : The Jacket is provided with Compound pressure gauge, safety valve, release valve and air out valve.
  • The Chamber : The Chamber is provided with Compound pressure gauge, plug screen, safety valve, release valve, powerful ejector (Baffle plate), vaccum breaker, pressure control switch, indicating lamp of operation and temperature indicator
  • Trolley : Only for rectangular model to load the material through Loading Chamber by trolley provided with self locking during loading and unloading.(Optional)
  • The Loading Chamber : It is framed structure with selves to load the material. The whole loading Chamber moved on the Trolley into the Chamber(Optional), Only for rectangular model.
  • Vaccum Breaker: The Chamber is Fitted with vaccum breaker to break the vaccum in case of formation of vaccum due to steam condensation.
  • Steam release valve : Two valves are provide for steam release from Boiler to chamber and one valve provided for steam release from Jacket to Chamber
  • Operating Pressure : Operating Pressure:-20psi (Adjustable)
  • Temperature Range: 5 °C above ambient to 135°C.
  • Temperature Controlled Microprocessor based PID Temperature controller with PT-100 Sensor
  • Temperature Resolution : 0.1°C
  • Temperature Accuracy : ± 1°C.
  • Power supply : 230volts, single phase, /440 volts, three phase, 50Hz, AC supply.

CYLINDRICAL

Sl.No Liters.Cap Model No                                     Inner chamber size (Width x Depth x Height )mm. Operating voltage and Power                                               
1 150 ACH-2030-316 500X750 440VAC,3 ph,50Hz,6KW
2 50 ACH-2230-316 550X750 440VAC,3 ph,50Hz,6KW
3 175 ACH-2236-316 550X900 440VAC,3ph,50Hz,9KW
4 210 ACH-2436-316 600X900 440VAC,3ph,50Hz,9KW

RECTANGULAR

Sl.No Liters.Cap Model No                                     Inner chamber size (Width x Depth x Height )mm. Operating voltage and Power                                                         
1 324 ACH-232 600X900X600 440V AC,3 phase,50Hz,18KW
2 432 ACH-242 600X1200X600 440V AC,3 phase,50Hz,24KW
3 648 ACH-243 600X1200X900 440V AC,3 phase,50Hz,27KW
4 810 ACH-253 600X1500X900 440V AC,3 phase,50Hz,36KW

VERTICAL LAMINAR AIR FLOW CABINET/HORIZONTAL LAMINAR AIR FLOW CABINET

Laminar
  • Cleanliness : Class 100
  • Velocity : 90 FPM ±20%
  • Hepa Filter : 99.999 % efficiency for particles >0.3 µ m
  • Pre-Filter : 85 %efficiency for particles >0.5 µ m (Washable)
  • Blower : High efficient centrifugal type with lifetime lubricated bearings
  • Light : High intensity, low wattage >800 LUX
  • Noise Level : <55 db A
  • Standard Accessories : Air/gas cock and mains power socket (16A)
  • Power Supply : 220-230 V, 50 Hz.
  • Work Table : 304/316 grade Stainless Steel work table
  • Filtration : Doubled filtered air blows in laminar flow through the worktable at designed velocity of 100 ft/min, +/- 20%
  • Leakage And Seating : 100%leak proof fittings ensures against contamination provides a comfortable ‘ sit down’ working position with footrest.
  • Cabinet : Cabinet made of Complete CRC mild steel and finished with powder coated/ stainless steel 304/ 316 grade without variation.
  • Accessories : Supplied with manometer, electrical controls Switches for illumination light on, UV Light on, Blower on and other standards provisions.
  • Front Door : Optional: Pneumatic front door open system with counter weight mechanism. (Optional)

Vertical Laminar Air Flow Cabinet

Sl.No Model No Working Cabin Size [ WXDXH] cm
1 LAF-V-2 2’x2’x2’
2 LAF-V-3 3’x2’x2’
3 LAF-V-4 4’x2’x2’
4 LAF-V-6 6’x2’x2’

Horizontal Laminar Air Flow Cabinet

Sl.No Model No Working Cabin Size [ WXDXH] cm
1 LAF-H-2 2’x2’x2’
2 LAF-H-3 3’x2’x2’
3 LAF-H-4 4’x2’x2’
4 LAF-H-6 6’x2’x2’

VACCUM OVEN

vacum oven
  • Design : Double walled
  • Inner chamber : Stainless steel 304/316 Grade.
  • Outer chamber : Outer chamber made of mild steel and finished with powder coated/ stainless steel 304/ 316 grade.
  • Insulation : Insulation between inner and outer chamber is filled with high grade glass wool
  • Heaters : Memmert type Air Heaters are made of high grade Kanthal wires of suitable wattage, wound on the all around the Chamber.
  • Gasket : Silicon rubber gaskets with effective door locking system for 100% sealing to hold vaccum effectively.
  • Door Glass Window : The door has viewing tough glass window with leak proof sealed. Door, Hinges, lock Hinges made of SS- 304 grade
  • Accessories Fitted : It has vaccum gauge, vaccum release valve and vaccum inlet valve Trays: Two perforated/ plain removable stainless steel trays at the fixed distance.
  • Trays : Two perforated/ plain removable stainless steel trays at the fixed distance.
  • : Vaccum attainable : Vaccum attainable up to 670mm/Hg.
  • Temperature Range : 5 °C above ambient to 200°C.
  • Temperature controlled : Microprocessor based PID controller with dual display (Process value and set value), low and high limit setting and Cr Al thermocouple.
  • Temperature Resolution : 0.1°C
  • Temperature Accuracy : + 2°C
  • Temperature uniformity : + 8°C.
  • Power supply : 230 Volts, Single Phase, 50Hz, AC supply.

VACCUM OVEN Cylindrical

SL No Liters. Cap Cylindrical Model No Inner chamber size [WXD] Inches Outer chamber size [ WXDXH] cm Power in[watts]
1 18 VO9d12 9”dia x 12”D 570x440x660 400
2 22 VO12d12 12”diax12” D 660x490x740 475
3 27 VO12d15 12”diax15”D 490x530x 645 500
4 33 VO12d18 12”diax 18”D 600
5 51 VO15d18 15”diax18”D 700
6 74 VO18d18 18”diax18”D 565x 600x 690 800
7 123 VO20d24 20” dia x 24” 685x750x 810 1100

VACCUM OVEN Rectangular

SL No Liters. Cap Cylindrical Model No Inner chamber size [WXD] Inches Outer chamber size [ WXDXH] cm Power in[watts]
1 28 VO121212 12”x12”x12” 570x440x660 500
2 35 VO121215 12”x12”x15” 600
3 44 VO121515 12”x15”x15” 490x530x 690 700
4 64 VO141420 14”x 14”x20” 800
5 78 VO151818 15” x18” x18” 565 600x 760 900
6 91 VO202424 18” x18” x18” 650 x 600x760 1000
7 189 VO242424 20”x24”x24” 685x750x 910 1300
8 226 VO202424 24”x24”x24” 785 x750x 910 1500

RECTANGULAR MUFFLE FURANCE

VERTICALMUFFLE FURNACE
  • Design : Double walled.
  • Inner chamber : made of Ceramic muffle wound on kanthal A1 heating elements and embedded with high quality ceramic cement to avoid heat loss.
  • Outer chamber : made of mild steel and finished with powder coated/ stainless steel 304 grade / 316 grade.
  • Heaters : made of high grade Kanthal A1 wires of suitable wattage.
  • Insulation : Gap between muffle and outer walls insulated with high quality light weight ceramic fiber.
  • Gasket : Asbestos rope gaskets for the door to avoid air leakage and temperature loss of Muffle furnace.
  • Temperature Range : 5ºC. Above ambient to 1000°C /1100°C /1200°C. (optional)
  • Temperature Resolution/Sensitivity : + 0.1°C up to 999°Cand above that 1°C
  • Temperature Accuracy : + 2°C
  • Front Panel: Front panel of our units comprises of mains on/off rocker switch, temperature controller and instruction manual.
  • Control Panel: Control panel of our units comprises of mains on/off rocker switch, temperature controller, heater fuse, solid state relay/ DC relays and wiring.
  • Power supply : 230volts single phase /440 volts three phase (optional) 50Hz, AC supply.
  • Temperature controlled : by Microprocessor based PID temperature controller with dual display (Process value and set value), low and high limit setting, time base controller and CrAl thermocouple.
Sl.No Inner chamber size[ WXDXH] mm Outer chamber size [ WXDXH] mm (include panel board & door) Power in KW[watts]
1 100x225x100 420x520x650 2
2 125x250x125 2.5
3 150x300x150 460x650x720 3
4 200x300x200 500x650x760 4.5
5 225x450x225 530x800x800 7.5 to 9

VERTICAL MUFFLE FURNACE

VERTICALMUFFLE FURNACE
  • Outer chamber of the Instrument made of Thick mild steel finished with powder coated.
  • Inner ceramic board muffle placed vertical sideways Silicon carbide rod heating elements and embedded with high quality ceramic board and ceramic fiber to avoid heat loss.In between muffle and outer walls insulated with high quality ceramic board and light
  • weight ceramic fiber.
  • Temperature range 5ºC. Above ambient to 1450 º C.
  • Accuracy +/- 5 ºC.
  • Temperature controlled by Microprocessor based PID controller with dual display (Process value and set value), low and high limit setting.
  • Heating Element: Silicon Carbide Rod with 5 KW thyristerised Controller. PTPT RH thermocouple
  • The working chamber size given below.
Sl.No Inner chamber size[ WXDXH] mm Outer chamber size [ WXDXH] mm (include panel board & door) Power in KW[watts] Temperature max
1 150x300x150 560x700x750 5 1450ºC

BIO SAFETY CABINET

BIO SAFETY CABINET

Construction Powder coated steel construction . designed to meet the filtration, illumination , noise and vibration providing particle free air to meet class 100 conditions. Doubled filtered air blows in laminar flow through the worktable at designed velocity of 100 ft/min, +/- 20%. HEPA filter has an efficiency rating as high as 99.99% with cold DOP and 99.97% with hot DOP. All components are of superior quality to give a fine combining aesthetic appeal, functioning utility and efficiency. The hole unit is easily detachable and portable. 100%leak proof fittings ensures against contamination provides a comfortable ‘ sit down’ working position with footrest. Half round ends on the S.S working table ensures comfort to the hands. Uniform perforated mesh give good look & protection with easy cleaning. Complete powder coated steel construction without variation or rusting. Supplied with manometer, electrical controls and other standards provisions. Scientifically designed ducting and blowers ensures against perfect air volume of 100 feet/minute. Uniform well insulated S.S. work table. Single piece aerosol HEPA FILTER ensures against dead air space inside the working area. Pneumatic front door open system with counter weight mechanism

Sl.no Size(LXBXH)
1 2’x2’x2’
2 3’x2’x2’
3 4’x2’x2’
4 6’x2’x2’

HUMIDITY CHAMBER/ STABILITY CHAMBER

humidity chamber
  • Design: Double walled, the motor fixed at the back side. The motorized forced air circulation to maintain uniform temperature inside the chamber.
  • Inner chamberStainless steel 304/316 Grade.
  • Outer chamberOuter chamber made of mild steel and finished with powder coated/ stainless steel 304/ 316 grade.
  • DoorsThe door is provided with rubber gasket door closer. The outer door is made of mild steel sheet and finished with powder coated. The Inner door is made of stainless steel sheet of grade 304/316. The door is provided with latch type lock and Bakelite/PVC handle.
  • Inner Glass Door :Inner full- length glass door is provided to view the samples without disturbing the temperature
  • Insulation Insulation between inner and outer chamber is filled with high grade glass wool.
  • Wheels : The unit is mounted on a sturdy steel frame with cast iron wheels for easy movement [for higher capacity only.]
  • Conditioning system : The triple walled back of the instrument is provided with air circulation fans. The chamber is equipped with a vertical recalculating conditioning stream of air sucking from the top of the inner chamber and allows passing through the back side of the inner chamber duct and carrying heating/cooling/humidity which enters from the bottom of the chamber this process continuous to maintain uniformity throughout the chamber.
  • Trays The unit is provided with 3 Nos. Mesh type removable Stainless Steel Rod trays at a Fixed Distance. Heating: Indirect heating system is provided in our units, and air heater which is made of high grade Kanthal heating wires of suitable wattage and is fixed at back side of the inner duct near the circulation fan. The warm air is evenly distributed throughout the chamber through efficient motor fans ensuring very good temperature sensitivity.
  • Heating : Indirect heating system is provided in our units, and air heater which is made of high grade Kanthal heating wires of suitable wattage and is fixed at back side of the inner duct near the circulation fan. The warm air is evenly distributed throughout the chamber through efficient motor fans ensuring very good temperature sensitivity.
  • Cooling : An energy efficient cooling unit is installed in our instrument hermetically sealed compressors. These compressors are the heavy duty industrial type noise free, vibration free and air cooled Compressors start in sequence to protect the unit from overloading. We use CFC free environmentally friendly refrigerant and compressors of Kirloskar/Tecumseh make, conforming to latest international standards and guidelines
  • HumidityHumidity generation is incorporated in our Instruments by means of aerosol humidity generator or by steam boiler provided at the back of the outer chamber which produces the steam enters inside the inner chamber to maintain required humidity. Lower humidity ranges are attainable with an optional auxiliary dryer system (ONLY OPTIONAL.)
  • Temperature controlled : Microprocessor based PID Temperature controller with PT-100 Sensor.
  • Humidity Controlled : Microprocessor based RH controller cum indicator with direct reading RH sensor.
  • Temperature Range : Temperature range o10°C to 60°C.
  • Humidity Range : From Ambient to 95% (As per the humidity Requirements)
  • Temperature Resolution: 0.1°C
  • Humidity Resolution: 0.1%.RH
  • Temperature Accuracy : ±1/2/3°C
  • Humidity Accuracy: ±3/ 5%.RH
  • Power supply ; 230volts, single phase, /440 volts, three phase, 50Hz, AC supply.

HUMIDITY CHAMBER Temp +10°C to 65°C Humidity 5% above ambient to 95 % Rh-Inner-SS-316grade-Outer-SS-304 Grade.

Sl.No Liters. Cap cubic/ feet Model No                         Inner chamber size[ WXDXH] cm Outer chamber size[ WXDXH] cm Power in[watts]
1 165/6 HC-6-GMP -C 50x 45x 75 64x90x150 1500
2 285/10 HC-12-GMP -C 58X55X90 73x102x166 2000
3 340/12 HC-10-GMP -C 60x 55x 105 74x103x183 3000

HUMIDITY CHAMBER Temp 5°C above Ambient to 65°C

Sl.No Liters. Cap cubic/ feet Model No                         Inner chamber size[ WXDXH] cm Outer chamber size[ WXDXH] cm Power in[watts]
1 165/6 HC-6-GMP -C 50x 45x 75 64x90x150 1500
2 285/10 HC-12-GMP -C 58X55X90 73x102x166 2000
3 340/12 HC-10-GMP -C 60x 55x 105 74x103x183 3000

STABILITY CHAMBER

stability chamber
  • Instruments: Double walled, the motor fixed at the back side. The motorized forced air circulation to maintain uniform temperature inside the chamber.
  • Inner chamber made of stainless steel 304 grade / 316 grade.(matt or polished finish)optional.
  • Outer chamber made of mild steel and finished with powder coated/ stainless steel 304 grade / 316 grade.(matt or polished finish) optional.
  • Doors Inner full- length glass door to view the samples without disturbing the temperature. and outer Mild steel door finished with powder coated/ SS 304 grade (optional) door with rubber gasket and lock.
  • Caster Wheels for easy movable for higher capacity only.
  • Heaters made of high grade Kanthal wires of suitable wattage Tubular air heater for heating.
  • Cooling Hermetically sealed compressor for cooling and CFC free gas.
  • Insulation Gap of 75 mm between inner and outer chamber is filled with high grade glass wool insulation.
  • Gasket rubber gaskets for the door to avoid air leakage and temperature loss of humidity chamber.
  • Trays Two/ Three removable stainless steel Mesh trays at the fixed distance.
  • Temperature Range: +5 °C to 60°C.
  • Temperature Resolution /Sensitivity: 0.1°C
  • Temperature Accuracy : + 0.5°C /1°C
  • Temperature Uniformity: + 5°C
  • Humidity range 50% to 95%.
  • RH accuracy +/- 5%RH.
  • Humidity creation water droplets falling on the high speed motor fan blade , which converts water droplets into fine particles of vapors ,enter in to the chamber to create humidity.
  • Front Panel: Front panel consists of mains ON/OFF, cooling on heating on and humidity on rocker switches, temperature and humidity controller and instruction manual.
  • Control Panel: Control pane consists of mains ON/OFF rocker switches, temperature and humidity controller, heater, humidity, compressor and motor fuses, solid state relay/ DC relays and wiring.
  • Power supply 230volts/440 volts, single phase /three phase 50Hz, AC supply.
  • Temperature controlled by Microprocessor based Digital temperature and Humidity controller with dual display PT-100 sensor Rh sensor.
Sl.No Liters./cubic Cap/ feet Inner chamber size[ WXDXH] cms Outer chamber size[ WXDXH] cms Power in[watts]
1 112/4 50x 45x 50 63x94x98 1500
2 165/6 50x 45x 75 64x90x150 2000
3 285/10 58X55X90 73x102x166 2500
4 340/12 60x 55x 105 74x103x183 3000

STABILITY CHAMBER

stability chamber
  • Instruments: Double walled, the motor fixed at the back side. The motorized forced air circulation to maintain uniform temperature inside the chamber.
  • Inner chamber made of stainless steel 304 grade / 316 grade.(matt or polished finish)optional.
  • Outer chamber made of mild steel and finished with powder coated/ stainless steel 304 grade / 316 grade.(matt or polished finish) optional.
  • Doors Inner full- length glass door to view the samples without disturbing the temperature. and outer Mild steel door finished with powder coated/ SS 304 grade (optional) door with rubber gasket and lock.
  • Caster Wheels for easy movable for higher capacity only.
  • Heaters made of high grade Kanthal wires of suitable wattage Tubular air heater for heating.
  • Cooling Hermetically sealed compressor for cooling and CFC free gas.
  • Insulation Gap of 75 mm between inner and outer chamber is filled with high grade glass wool insulation.
  • Gasket rubber gaskets for the door to avoid air leakage and temperature loss of humidity chamber.
  • Trays Two/ Three removable stainless steel Mesh trays at the fixed distance.
  • Temperature Range: +5 °C to 60°C.
  • Temperature Resolution /Sensitivity: 0.1°C
  • Temperature Accuracy : + 0.5°C /1°C
  • Temperature Uniformity: + 5°C
  • Humidity range 50% to 95%.
  • RH accuracy +/- 5%RH.
  • Humidity creation water droplets falling on the high speed motor fan blade , which converts water droplets into fine particles of vapors ,enter in to the chamber to create humidity.
  • Front Panel: Front panel consists of mains ON/OFF, cooling on heating on and humidity on rocker switches, temperature and humidity controller and instruction manual.
  • Control Panel: Control pane consists of mains ON/OFF rocker switches, temperature and humidity controller, heater, humidity, compressor and motor fuses, solid state relay/ DC relays and wiring.
  • Power supply 230volts/440 volts, single phase /three phase 50Hz, AC supply.
  • Temperature controlled by Microprocessor based Digital temperature and Humidity controller with dual display PT-100 sensor Rh sensor.
Sl.No Liters./cubic Cap/ feet Inner chamber size[ WXDXH] cms Outer chamber size[ WXDXH] cms Power in[watts]
1 112/4 50x 45x 50 63x94x98 1500
2 165/6 50x 45x 75 64x90x150 2000
3 285/10 58X55X90 73x102x166 2500
4 340/12 60x 55x 105 74x103x183 3000

SEED GERMINATOR

stability chamber
  • Design : Double walled
  • Inner chamber : Stainless steel 304/316 Grade.
  • Outer chamber : Outer chamber made of mild steel and finished with powder coated/ stainless steel 304/ 316 grade.
  • Doors : The door is provided with rubber gasket door closer. The outer door is made of mild steel sheet and finished with powder coated. The Inner door is made of stainless steel sheet of grade 304. The door is provided with latch type lock and Bakelite/PVC handle.
  • Insulation : Insulation between inner and outer chamber is filled with high grade glass wool.
  • Inner Glass Door :Inner full- length glass door is provided to view the samples without disturbing the temperature
  • Wheels : The unit is mounted on a sturdy steel frame with cast iron wheels for easy movement [for higher capacity only.]
  • Conditioning system : The triple walled back of the instrument is provided with air circulation fans. The chamber is equipped with a vertical recalculating conditioning stream of air sucking from the top of the inner chamber and allows passing through the back side of the inner chamber duct and carrying heating/cooling/humidity which enters from the bottom of the chamber this process continuous to maintain uniformity throughout the chamber.
  • Trays The unit is provided with 3 Nos. Mesh type removable Stainless Steel Rod trays at a Fixed Distance.
  • Heating : Indirect heating system is provided in our units, and Tubular air heater which is made of high grade Kanthal heating wires of suitable wattage and is fixed at back side of the inner duct near the circulation fan. The warm air is evenly distributed throughout the chamber through efficient motor fans ensuring very good temperature sensitivity.
  • Cooling : An energy efficient cooling unit is installed in our instrument hermetically sealed compressors. These compressors are the heavy duty industrial type noise free, vibration free and air cooled Compressors start in sequence to protect the unit from overloading. We use CFC free environmentally friendly refrigerant and compressors of Kirloskar/Tecumseh make, conforming to latest international standards and guidelines
  • Humidity : Humidity generation is incorporated in our Instruments by means of aerosol humidity generator
  • Illumination : Illumination is provided by one/two florescent tube on either side of inner chamber and it is controlled by cyclic timer.
  • Temperature Range : Microprocessor based PID Temperature controller with PT-100 Sensor
  • Humidity Range : 95% RH
  • Temperature Resolution: 0.1°C
  • Humidity Resolution: 0.1%.RH
  • Temperature Accuracy : ±1/2/3°C
  • Humidity Accuracy: ±3/ 5%.RH
  • Power supply ; 230volts, single phase, /440 volts, three phase, 50Hz, AC supply.
Sl.No Liters./cubic Cap/ feet Model No Inner chamber size[ WXDXH] cms Outer chamber size[ WXDXH] cms Power in[watts]
1 165/6 SG-6 50x 45x 75 64x90x150 1500
2 285/10 SG-10 58X55X90 73x102x166 2000
3 340/12 SG-12 60x 55x 105 74x103x183 3000

BLOOD BANK REFRIGERATOR

BLOOD BANK REFRIGERATOR

DEEP FREEZER VERTICAL/ HORIZANTAL

deep freezer
  • Design : Double walled
  • Inner chamber : Stainless steel 304/316 Grade.
  • Outer chamber : Outer chamber made of mild steel and finished with powder coated/ stainless steel 304/ 316 grade.
  • Doors : The door is provided with rubber gasket door closer. The outer door is made of mild steel sheet and finished with powder coated. The Inner door is made of stainless steel sheet of grade 304. The door is provided with latch type lock and Bakelite/PVC handle.
  • Wheels : The unit is mounted on a sturdy steel frame with cast iron wheels for easy movement [for higher capacity only.]
  • Trays : The unit is provided with 3 Nos. Perforated type removable Stainless Steel sheet trays at a Fixed Distance.
  • Insulation : The chamber walls are hermetically sealed and insulated with 3” of high density PUF for both body and door.
  • Cooling : An energy efficient cooling unit is installed in our instrument hermetically sealed compressors. These compressors are the heavy duty industrial type noise free, vibration free and air cooled Compressors start in sequence to protect the unit from overloading. We use CFC free environmentally friendly refrigerant and compressors of Kirloskar/Tecumseh make, conforming to latest international standards and guidelines
  • Condenser : Large air cooled finned condenser with front to back air flow over the compressors resulting in cooler compressors and longer life to the freezer.
  • HCFC & CFC –Free Refrigeration System :Heat control cascade system allows for quick temperature pull down .All connections are sil-fos brazed through the refrigeration system. Refrigeration system runs only on demand and uses down feed refrigerant flow. Because of the unique design of the Freezers, the pressure in the refrigeration system is held very low, eliminating excessive heat buildup. This low pressure allows the freezer to operate efficiently, extending compressor life. Freezers use R-404a & R-508b low temperature CFC-Free refrigerant.
  • Oil Separator : Freezerwarm - upsdue to oil logging are prevented by using a specially designed refrigerant flow and unique oil separator that removes 99.99% of the oil from the refrigeration gas and returns the oil to the compressor.
  • Temperature Controlled: Microprocessor based PID Temperature controller with PT-100 Sensor.
  • Temperature Range : Temperature range -20°C/-30°C/-40°C/-80°C min.
  • Temperature Resolution: 0.1°C
  • Temperature Accuracy : ±3°C to 4°C
  • Power supply : 230volts, single phase, /440 volts, three phase, 50Hz, AC supply.
Sl.No Liters./cubic Cap/ feet Model No                   Inner chamber size[WXDXH] cm Power in [watts]
1 165/6 DFV-6-20 50x 45x 75 1500
2 285/10 DFV-10-20 58X55X90 2000
3 340/12 DFV-12-20 60x 55x 105 3000

HOT PLATE

hot plate
  • Top Plate : Made of thick plate SS 304/316 grade
  • Outer Chamber : Outer chamber made of mild steel and finished with powder coated/ stainless steel 304/ 316 grade.
  • Insulation : Top Plate insulated with high grade Ceramic Fiber.
  • Heaters : Coiled Air Heaters are made of high grade Kanthal wires of suitable wattage.
  • Temperature Range : 5 °C above ambient to 300°C.
  • Temperature Controller / Resolution/ accuracy : Thermostatic Control / 5°C / ± 10°C.
  • Temperature Controller / Resolution/ accuracy : Microprocessor based PID temperature controller with dual display (Process value and set value), low and high limit setting with Cr Al thermocouple and Timer control (optional). / 0.1°C / ± 2°C.
  • Power Supply : 230 Volts Single Phase 50Hz, AC supply.

HOT PLATE - 300°C-Top Plate -304 grade-Outer-MS Powder coated

Sl.No Model No Top Plate size [WXL]Inches Power in [watts]
1 HP-8 8" x 8" 1000
2 HP-12 12" x 12" 1500
3 HP-1218 12" x 18" 2000
4 HP-1824 18" x 24" 3000

INDUSTRIAL BURNING CHAMBER

 Burning-Chamber-2

UV CABINET

Uv-Cabinet

FUME HOOD

fume-hood

VACUUM PUMP

Vacuum-Pump

vacuum pump single stage ,50/100Lpm and maximum vacuum attainable 670mm Hg. Absolutely protable. All parts made from special graded Aluminum die cast material for light weight and good strength. Diaphragrams are made of special g2-ply nylon reinforced neoprene rubber. Valves are made of SS 316 grade material. Built-in micro suction filter. Extra large bearing for trouble free and smooth running. Noiseless performance. . No lubricant required. Totally oil free construction

BUNSEN BURNER

 Bunsen-Burner

WATER DISTILL UNIT

 Water-Still

ORBITAL SHAKING INCUBATOR

  • Design : Double walled
  • Inner Chamber : Inner chamber made of stainless steel 304/316 Grade
  • Outer Chamber : Outer chamber made of mild steel and finished with powder coated/ stainless steel 304/ 316 grade.
  • Insulation : Insulation between inner and outer chamber is filled with high grade glass wool.
  • Conditioning system Air Circulation Fan Motor : The triple walled back of the instrument is provided with air circulation fans. The chamber is equipped with a vertical recalculating conditioning stream of air sucking from the top of the inner chamber and allows passing through the back side of the inner chamber duct and carrying heating/cooling/humidity which enters from the bottom of the chamber this process continuous to maintain uniformity throughout the chamber.
  • Heating : Indirect heating system is provided in our units, and air heater which is made of high grade Kanthal heating wires of suitable wattage and is fixed at back side of the inner duct near the circulation fan. The warm air is evenly distributed throughout the chamber through efficient motor fans ensuring very good temperature sensitivity.
  • Outer Door : Inner stainless steel and Outer made of Mild steel finished with powder coated. It is having Glass window to view without disturbing the samples.
  • Gasket : Rubber gasket and latch is provided for the door is provided for the door to avoid air leakage and temperature loss from Instrument.
  • Trays : One perforated removable stainless steel trays at the fixed distance.
  • Speed Controller : It is having orbital motion control by RPM Indicator cum controller
  • Orbital Shaker : Orbital shaking by DC motor with D C drive of speed 50-250 RPM with variable speed control.
  • Orbital movement : Movement range25 mm in orbital motion.
  • Flask capacity : 250ml flask of 16 Nos. / 500ml flask of 9 Nos. / mixed
  • Temperature Range : +5°C above ambient to 60°C / 10°C to 60°C
  • Temperature Controller : Microprocessor based PID temperature controller with dual display (Process value and set value), low and high limit setting with PT-100 Sensor and Timer control (optional).
  • Temperature Resolution : 0.1°C
  • Temperature Accuracy : ± 1°C.
  • Temperature Accuracy : ± 2°C.
  • Temperature Uniformity : ± 2°C.
  • Power Supply : 230 Volts Single Phase 50Hz, AC supply.

ORBITAL SHAKING INCUBATOR-Temperature Range+10°C to 60°C

Sl.No Liters. Cap cubic/ feet Model No                         Inner chamber size [ WXDXH] cm Outer chamber size [ WXDXH] cm Power in watts
1 125/4.5 Orb-ShI-C 55 x 55 x 50 2000

ORBITAL SHAKING INCUBATOR-Temperature Range+5°C above ambient to 60°C

Sl.No Liters. Cap cubic/ feet Model No                         Inner chamber size [ WXDXH] cm Outer chamber size [ WXDXH] cm Power in watts
1 125/4.5 Orb-ShI 55 x 55 x 50 2000

ORBITAL SHAKING INCUBATOR

  • Design : Double walled
  • Inner Chamber : Inner chamber made of stainless steel 304/316 Grade
  • Outer Chamber : Outer chamber made of mild steel and finished with powder coated/ stainless steel 304/ 316 grade.
  • Insulation : Insulation between inner and outer chamber is filled with high grade glass wool.
  • Conditioning system Air Circulation Fan Motor : The triple walled back of the instrument is provided with air circulation fans. The chamber is equipped with a vertical recalculating conditioning stream of air sucking from the top of the inner chamber and allows passing through the back side of the inner chamber duct and carrying heating/cooling/humidity which enters from the bottom of the chamber this process continuous to maintain uniformity throughout the chamber.
  • Heating : Indirect heating system is provided in our units, and air heater which is made of high grade Kanthal heating wires of suitable wattage and is fixed at back side of the inner duct near the circulation fan. The warm air is evenly distributed throughout the chamber through efficient motor fans ensuring very good temperature sensitivity.
  • Outer Door : Inner stainless steel and Outer made of Mild steel finished with powder coated. It is having Glass window to view without disturbing the samples.
  • Gasket : Rubber gasket and latch is provided for the door is provided for the door to avoid air leakage and temperature loss from Instrument.
  • Trays : One perforated removable stainless steel trays at the fixed distance.
  • Speed Controller : It is having orbital motion control by RPM Indicator cum controller
  • Orbital Shaker : Orbital shaking by DC motor with D C drive of speed 50-250 RPM with variable speed control.
  • Orbital movement : Movement range25 mm in orbital motion.
  • Flask capacity : 250ml flask of 16 Nos. / 500ml flask of 9 Nos. / mixed
  • Temperature Range : +5°C above ambient to 60°C / 10°C to 60°C
  • Temperature Controller : Microprocessor based PID temperature controller with dual display (Process value and set value), low and high limit setting with PT-100 Sensor and Timer control (optional).
  • Temperature Resolution : 0.1°C
  • Temperature Accuracy : ± 1°C.
  • Temperature Accuracy : ± 2°C.
  • Temperature Uniformity : ± 2°C.
  • Power Supply : 230 Volts Single Phase 50Hz, AC supply.

ORBITAL SHAKING INCUBATOR-Temperature Range+10°C to 60°C

Sl.No Liters. Cap cubic/ feet Model No                         Inner chamber size [ WXDXH] cm Outer chamber size [ WXDXH] cm Power in watts
1 125/4.5 Orb-ShI-C 55 x 55 x 50 2000

ORBITAL SHAKING INCUBATOR-Temperature Range+5°C above ambient to 60°C

Sl.No Liters. Cap cubic/ feet Model No                         Inner chamber size [ WXDXH] cm Outer chamber size [ WXDXH] cm Power in watts
1 125/4.5 Orb-ShI 55 x 55 x 50 2000

ORBITAL SHAKING INCUBATOR

  • Outer Chamber : The body of the mantle is spun one piece form non-rusting Aluminum duly staving Enamel painted.
  • Insulation : : Insulation between Mantle and outer chamber is filled with high grade glass wool withstand maximum Temperature 350° Cli>
  • Header : Air Heaters are made of high grade Kanthal wires of suitable wattage.
  • Temperature Range : 5°C above ambient to 350°C.
  • Mantle : All heating mantles are lagged with special grade mineral wool. MANTLE HAS NO WARRANTY
  • Front Panel : The panel is provided with on-off switch, energy control knob pilot lamp etc.
  • Power Supply : : 230 Volts, Single Phase, 50Hz and AC supply.
  • Temperature Controller : Thermostatic Control (optional) at an extra cost. For up to 300°C

Heating Mantle -350°C

Sl.No Liters. Cap cubic/ feet Model No
1 500ml HM-500
2 1 HM-1
3 2 HM-2
4 3 HM-3
5 5 HM-5

SOXLET EXTRACTION- Mantle Type

  • Top sheet : made of stainless steel 304 Grade/ 316 grade.
  • Outer Chamber : Outer chamber made of mild steel and finished with powder coated/ stainless steel 304/ 316 grade. Insulation: Insulation between top mantle to body is filled with high grade glass wool to withstand maximum Temperature 350° C
  • Mantle : All heating mantles are lagged with special grade mineral wool. MANTLE HAS NO WARRANTY
  • Temperature Controller : Temperature controlled by energy regulator/ Thermostatic Control (optional) at an extra Cost. For up to 300°C
  • No of Mantle : 6 extraction places of 6 Nos. heating mantle suitable for 500 ml flasks Complete with stand, without clamp holder
  • Temperature Range : 5 °C above ambient to 350°C.
  • Power Supply : 230 Volts Single Phase 50Hz, AC supply.

Heating Mantle -350°C

Sl.No Top sheet Mantle Capacity in Liters Model No
1 SS-304 500ml SE-6-304
2 SS-316 500ml SE-6-316

BIO SAFETY CABIN

  • Cleanliness : Class 100
  • Velocity : 90 FPM ±20%
  • Hepa Filter : 99.999 % efficiency for particles >0.3 μ m
  • Pre-Filter : 85 %efficiency for particles >0.5 μ m (Washable)
  • Blower : High efficient centrifugal type with lifetime lubricated bearings
  • Light : High intensity, low wattage >800 LUX
  • Noise Level : <55 db A
  • Standard Accessories : Air/gas cock and mains power socket (16A)
  • Power supply : 230volts, single phase, 50Hz, AC supply.
  • Work Table : 304/316 grade Stainless Steel work table
  • Filtration : Doubled filtered air blows in laminar flow through the worktable at designed velocity of 100 ft/min, +/- 20%
  • Leakage and Seating : 100%leak proof fittings ensures against contamination provides a comfortable ‘sit down’ working position with footrest.
  • Accessories : Supplied with manometer, electrical controls Switches for illumination light on, UV Light on, Blower on and other standards provisions.
  • Front Door : Pneumatic front door open system with counter weight mechanism.
  • Exhaust assembly : 300 CFM, ducting by PVC pipe with rain guard - Dia. 150mm
  • Viral burn out -Class 1 : Viral Burn Out with 50% recirculation and 50% exhaust
  • Viral burn out -Class2A : Viral Burn Out with 70% recirculation and 30% exhaust (Optional)
  • Viral burn out -Class2B : Viral Burn Out with 30% recirculation and 70% exhaust (Optional)
  • Viral burn out -Class3 : Viral Burn Out with 100% recirculation and exhaust (Optional)
  • Exhaust Motor : Variable Speed DC Motor as per the Air flow Required (Optional)

Recirculation TypeMs body and SS table top-2014

Sl.No Model No Working Cabin Size [ WXDXH] cm
1 BSC-2 2’x2’x2’
2 BSC-3 3’x2’x2’
3 BSC-4 4’x2’x2’
4 BSC-6 6’x2’x2’

MECHINICAL SHAKER

  • Chamber Design : chamber made of mild steel and finished with powder coated
  • Speed Control : DC motor with D C drive of speed 50-250 RPM with variable speed control
  • Motion : Orbital motion
  • RPM Indicator : Digital RPM Indicator
  • Timer : digital timer of 999 minutes.
  • Platform Size : 45 cm x 45 cm Length x width.
  • Orbital movement : Movement range25 mm in orbital motion.
  • Flask capacity : 250ml flask of 16 Nos. or 500ml flask of 9 Nos, or mixed.
  • Control Panel : consists of ON/OFF mains switch, timer ON/OFF switch, Variable RPM Controller and shaker on switch
  • Power Supply : 230 Volts Single Phase 50Hz, AC supply.

Recirculation TypeMs body and SS table top-2014

Sl.No Model No Platform size [ L x B] cm Power in watts
1 MS-4545 45 x 45 2000